Nominal Cross Sectional Area Of Conductor | Number / Nom. Dia Of Wires* | Thickness Of Insulation (Nom) | General Purpose Compound | HOFR Compound | ||||
---|---|---|---|---|---|---|---|---|
DUTY CYCLE | ||||||||
Amps. | Amps. | |||||||
mm2 | mm | mm | 100% | 60% | 30% | 100% | 60% | 30% |
16 | 510/0.2 | 2.0 | 94 | 121 | 172 | 135 | 174 | 246 |
25 | 796/0.2 | 2.0 | 125 | 161 | 228 | 177 | 228 | 343 |
35 | 1114/0.2 | 2.0 | 156 | 201 | 285 | 221 | 285 | 403 |
50 | 707/0.3 | 2.2 | 197 | 254 | 360 | 279 | 360 | 509 |
70 | 990/0.3 | 2.4 | 248 | 320 | 453 | 352 | 454 | 643 |
95 | 1344/0.3 | 2.6 | 299 | 386 | 546 | 424 | 547 | 774 |
Nominal Cross Sectional Area Of Conductor | Number/Nom. Dia Of Wires* | Thickness Of Insulation (Nom) | General Purpose Compound | HOFR Compound | ||||
---|---|---|---|---|---|---|---|---|
DUTY CYCLE | ||||||||
Amps. | Amps. | |||||||
mm2 | mm | mm | 100% | 60% | 30% | 100% | 60% | 30% |
25 | 355/0.3 | 2.0 | 100 | 129 | 183 | 144 | 186 | 263 |
35 | 495/0.3 | 2.0 | 123 | 159 | 225 | 176 | 227 | 321 |
50 | 707/0.03 | 2.2 | 155 | 200 | 283 | 222 | 287 | 405 |
70 | 990/0.3 | 2.4 | 196 | 253 | 358 | 280 | 361 | 511 |
95 | 1344/0.3 | 2.6 | 237 | 306 | 433 | 339 | 438 | 619 |
120 | 1697/0.3 | 2.8 | 283 | 365 | 517 | 404 | 522 | 738 |
Nominal Cross Sectional Of Conductor | Current Rating At A Maximum Duty Cycle Of | Max. Conductor Resistance At 20°C | Nom. Thickness Of Covering | ||||
---|---|---|---|---|---|---|---|
100% | 85% | 60% | 30% | 20% | ohm/km | mm | |
mm2 | Amp | Amp | Amp | Amp | Amp | ||
16 | 94 | 102 | 121 | 172 | 210 | 1.21 | 2.0 |
25 | 125 | 136 | 161 | 228 | 279 | 0.780 | 2.0 |
35 | 156 | 169 | 201 | 285 | 349 | 0.554 | 2.0 |
50 | 197 | 214 | 254 | 360 | 440 | 0.386 | 2.2 |
70 | 248 | 269 | 320 | 453 | 555 | 0.272 | 2.4 |
95 | 299 | 342 | 386 | 546 | 669 | 0.206 | 2.6 |
Nominal Cross Sectional Of Conductor | Current Rating At A Maximum Duty Cycle Of | Max. Conductor Resistance At 20°C | Nom. Thickness Of Covering | ||||
---|---|---|---|---|---|---|---|
100% | 85% | 60% | 30% | 20% | ohm / km | mm | |
mm2 | Amp | Amp | Amp | Amp | Amp | ||
16 | 94 | 135 | 146 | 174 | 246 | 1.21 | 2.0 |
25 | 125 | 177 | 192 | 228 | 343 | 0.780 | 2.0 |
35 | 156 | 221 | 240 | 285 | 403 | 0.554 | 2.0 |
50 | 197 | 279 | 303 | 360 | 509 | 0.386 | 2.2 |
70 | 248 | 352 | 382 | 454 | 643 | 0.272 | 2.4 |
95 | 299 | 424 | 460 | 547 | 774 | 0.206 | 2.6 |
Nominal Cross Sectional Of Conductor | Current Rating At A Maximum Duty Cycle Of | Max. Conductor Resistance At 20°C | Nom. Thickness Of Covering | ||||
---|---|---|---|---|---|---|---|
100% | 85% | 60% | 30% | 20% | ohm / km | mm | |
mm2 | Amp | Amp | Amp | Amp | Amp | ||
25 | 100 | 108 | 129 | 183 | 224 | 1.23 | 2.0' |
35 | 123 | 133 | 159 | 225 | 275 | 0.901 | 2.0 |
50 | 155 | 168 | 200 | 283 | 347 | 0.634 | 2.2 |
70 | 196 | 213 | 253 | 358 | 438 | 0.445 | 2.4 |
95 | 237 | 257 | 306 | 433 | 530 | 0.334 | 2.6 |
120 | 307 | 307 | 365 | 517 | 635 | 0.256 | 2.8 |
Nominal Cross Sectional Of Conductor | Current Rating At A Maximum Duty Cycle Of | Max. Conductor Resistance At 20°C | Nom. Thickness Of Covering | |||
---|---|---|---|---|---|---|
100% | 85% | 60% | 30% | ohm / km | mm | |
mm2 | Amp | Amp | Amp | Amp | Amp | |
25 | 144 | 156 | 186 | 263 | 1.23 | 2.0 |
35 | 173 | 191 | 227 | 321 | 0.901 | 2.0 |
50 | 222 | 241 | 287 | 405 | 0.634 | 2.2 |
70 | 280 | 304 | 361 | 511 | 0.445 | 2.4 |
95 | 339 | 368 | 438 | 617 | 0.334 | 2.6 |